Abstract
Renal T2 relaxation time, as part of quantitative MRI, is a promising noninvasive tool to quantify specific tissue composition (i.e., local microstructural magneto-chemical environment) of the kidney. Pathophysiological changes in the complex structural and functional organization of the kidney are considered in parts to be quantifiable with T2. A limited number of studies have been conducted, with promising results to detect fluid accumulations, edema (inflammation), and precise progression assessment of ADPKD patients. This is a strong motivation for further research in this field, with sophisticated and standardized measurement protocols, patient selection and preparations, and quality assurance measures, that is, comparative phantom measurements. This could ultimately lead to a more precise and personalized diagnosis (staging) and enable therapeutic monitoring, a highly needed tool for the management of chronic kidney disease.
| Original language | English |
|---|---|
| Title of host publication | Advanced Clinical MRI of the Kidney |
| Subtitle of host publication | Methods and Protocols |
| Publisher | Springer International Publishing |
| Pages | 125-132 |
| Number of pages | 8 |
| ISBN (Electronic) | 9783031401695 |
| ISBN (Print) | 9783031401688 |
| DOIs | |
| Publication status | Published - 01 Jan 2023 |
| Externally published | Yes |
ASJC Scopus subject areas
- General Medicine
Fingerprint
Dive into the research topics of 'T2 Mapping of the Kidney'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver