Real-time intensity based 2D/3D registration using kV-MV image pairs for tumor motion tracking in image guided radiotherapy

H. Furtado, E. Steiner, M. Stock, D. Georg, W. Birkfellner

Research output: Contribution to book/report/conference proceedingContribution to conference proceeding

1 Citation (Scopus)

Abstract

Intra-fractional respiratorymotion during radiotherapy is one of themain sources of uncertainty in dose application creating the need to extend themargins of the planning target volume (PTV). Real-time tumormotion tracking by 2D/3D registration using on-board kilo-voltage (kV) imaging can lead to a reduction of the PTV. One limitation of this technique when using one projection image, is the inability to resolve motion along the imaging beam axis. We present a retrospective patient study to investigate the impact of paired portal mega-voltage (MV) and kV images, on registration accuracy. We used data from eighteen patients suffering from non small cell lung cancer undergoing regular treatment at our center. For each patient we acquired a planning CT and sequences of kV and MV images during treatment. Our evaluation consisted of comparing the accuracy of motion tracking in 6 degrees-of-freedom(DOF) using the anterior-posterior (AP) kV sequence or the sequence of kV-MV image pairs. We use graphics processing unit rendering for real-time performance. Motion along cranial-caudal direction could accurately be extracted when using only the kV sequence but in AP direction we obtained large errors. When using kV-MV pairs, the average error was reduced from 3.3 mm to 1.8 mm and the motion along AP was successfully extracted. The mean registration time was of 190±35ms. Our evaluation shows that using kVMV image pairs leads to improved motion extraction in 6 DOF. Therefore, this approach is suitable for accurate, real-time tumor motion tracking with a conventional LINAC.

Original languageEnglish
Title of host publicationMedical Imaging 2014
Subtitle of host publicationImage Processing
PublisherSPIE
ISBN (Print)9780819498274
DOIs
Publication statusPublished - 2014
EventMedical Imaging 2014: Image Processing - San Diego, CA, United States
Duration: 16 Feb 201418 Feb 2014

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume9034
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2014: Image Processing
Country/TerritoryUnited States
CitySan Diego, CA
Period16/02/1418/02/14

Keywords

  • 2D/3D registration
  • CUDA
  • GPGPU
  • Image guided radiotherapy
  • Tumor motion management

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Atomic and Molecular Physics, and Optics
  • Biomaterials
  • Radiology, Nuclear Medicine and Imaging

Fingerprint

Dive into the research topics of 'Real-time intensity based 2D/3D registration using kV-MV image pairs for tumor motion tracking in image guided radiotherapy'. Together they form a unique fingerprint.

Cite this