Skip to main navigation Skip to search Skip to main content

Multicentre experience with two frozen elephant trunk prostheses in the treatment of acute aortic dissection

  • Tim Berger
  • , Gabriel Weiss
  • , Andreas Voetsch
  • , Zsuzsanna Arnold
  • , Maximilian Kreibich
  • , Bartosz Rylski
  • , Philipp Krombholz-Reindl
  • , Andreas Winkler
  • , Markus Mach
  • , Daniela Geisler
  • , Rainald Seitelberger
  • , Mathias Siepe
  • , Friedhelm Beyersdorf
  • , Martin Grabenwoeger
  • , Martin Czerny
  • , Roman Gottardi*
  • *Corresponding author for this work

Research output: Journal article (peer-reviewed) › Journal article

Abstract

OBJECTIVES: The aim of this study was to evaluate early- and mid-term outcome and aortic remodelling in patients undergoing implantation of 2 different frozen elephant trunk prostheses, either the Thoraflex™ hybrid (Vascutek, Inchinnan, UK) and the E-vita Open (Jotec Inc., Hechingen, Germany) for acute aortic dissection. METHODS: All consecutive patients [n = 88; median age 59 (49-67) years; 69% male] undergoing surgery with a frozen elephant trunk prosthesis for acute aortic dissection from August 2005 until March 2018 were included in this study. The Thoraflex™ device was implanted in 55 patients and the E-vita Open graft in 33 patients. RESULTS: Preoperative characteristics did not differ significantly between groups. There was also no statistically significant difference in postoperative outcome: in-hospital mortality (11% vs 12%; P > 0.99), stroke (18% vs 6%; P = 0.12) and spinal cord injury (6% vs 6%; P > 0.99). While there was no statistically significant difference in the occurrence of distal stent graft-induced new entries (16% vs 18%; P = 0.77), there was a significantly higher rate of secondary endovascular aortic interventions in the Thoraflex™ hybrid group (22% vs 0%; P = 0.003). There was a trend towards a higher rate of false lumen thrombosis at the level of the stent graft (74% vs 95%; P = 0.085) and was comparable at the thoraco-abdominal transition (53% vs 80%; P = 0.36) 1 year after implantation of the prostheses. CONCLUSIONS: In this comparison of 2 frozen elephant trunk prostheses, there is no evidence that different surgical techniques influence in-hospital outcome. At 1-year follow-up, patients who underwent implantation of the E-vita Open prosthesis showed a significantly reduced rate of secondary aortic interventions and a trend towards a higher rate of false lumen thrombosis which might be attributed to a longer coverage of the descending aorta due to a longer stent graft design and significantly more frequent implantation in zone 3.

Original languageEnglish
Pages (from-to)572-578
Number of pages7
JournalEuropean Journal of Cardio-thoracic Surgery
Volume56
Issue number3
DOIs
Publication statusPublished - 01 Sept 2019
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Aortic dissection
  • False lumen thrombosis
  • Frozen elephant trunk

ASJC Scopus subject areas

  • Surgery
  • Pulmonary and Respiratory Medicine
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Multicentre experience with two frozen elephant trunk prostheses in the treatment of acute aortic dissection'. Together they form a unique fingerprint.

Cite this