T1 - Low-Dose Image-Guided Pediatric CNS Radiation Therapy
T2 - Final Analysis From a Prospective Low-Dose Cone-Beam CT Protocol From a Multinational Pediatrics Consortium
AU - Alcorn, Sara R.
AU - Zhou, Xian Chiong
AU - Bojechko, Casey
AU - Rubo, Rodrigo A.
AU - Chen, Michael J.
AU - Dieckmann, Karin
AU - Ermoian, Ralph P.
AU - Ford, Eric C.
AU - Kobyzeva, Daria
AU - MacDonald, Shannon M.
AU - McNutt, Todd R.
AU - Nechesnyuk, Alexey
AU - Nilsson, Kristina
AU - Sjostrand, Hakan
AU - Smith, Koren S.
AU - Stock, Markus
AU - Tryggestad, Erik J.
AU - Villar, Rosangela C.
AU - Winey, Brian A.
AU - Terezakis, Stephanie A.
N1 - Publisher Copyright:
© The Author(s) 2020.
PY - 2020
Y1 - 2020
N2 - Background: Lower-dose cone-beam computed tomography protocols for image-guided radiotherapy may permit target localization while minimizing radiation exposure. We prospectively evaluated a lower-dose cone-beam protocol for central nervous system image-guided radiotherapy across a multinational pediatrics consortium. Methods: Seven institutions prospectively employed a lower-dose cone-beam computed tomography central nervous system protocol (weighted average dose 0.7 mGy) for patients ≤21 years. Treatment table shifts between setup with surface lasers versus cone-beam computed tomography were used to approximate setup accuracy, and vector magnitudes for these shifts were calculated. Setup group mean, interpatient, interinstitution, and random error were estimated, and clinical factors were compared by mixed linear modeling. Results: Among 96 patients, with 2179 pretreatment cone-beam computed tomography acquisitions, median age was 9 years (1-20). Setup parameters were 3.13, 3.02, 1.64, and 1.48 mm for vector magnitude group mean, interpatient, interinstitution, and random error, respectively. On multivariable analysis, there were no significant differences in mean vector magnitude by age, gender, performance status, target location, extent of resection, chemotherapy, or steroid or anesthesia use. Providers rated >99% of images as adequate or better for target localization. Conclusions: A lower-dose cone-beam computed tomography protocol demonstrated table shift vector magnitude that approximate clinical target volume/planning target volume expansions used in central nervous system radiotherapy. There were no significant clinical predictors of setup accuracy identified, supporting use of this lower-dose cone-beam computed tomography protocol across a diverse pediatric population with brain tumors.
AB - Background: Lower-dose cone-beam computed tomography protocols for image-guided radiotherapy may permit target localization while minimizing radiation exposure. We prospectively evaluated a lower-dose cone-beam protocol for central nervous system image-guided radiotherapy across a multinational pediatrics consortium. Methods: Seven institutions prospectively employed a lower-dose cone-beam computed tomography central nervous system protocol (weighted average dose 0.7 mGy) for patients ≤21 years. Treatment table shifts between setup with surface lasers versus cone-beam computed tomography were used to approximate setup accuracy, and vector magnitudes for these shifts were calculated. Setup group mean, interpatient, interinstitution, and random error were estimated, and clinical factors were compared by mixed linear modeling. Results: Among 96 patients, with 2179 pretreatment cone-beam computed tomography acquisitions, median age was 9 years (1-20). Setup parameters were 3.13, 3.02, 1.64, and 1.48 mm for vector magnitude group mean, interpatient, interinstitution, and random error, respectively. On multivariable analysis, there were no significant differences in mean vector magnitude by age, gender, performance status, target location, extent of resection, chemotherapy, or steroid or anesthesia use. Providers rated >99% of images as adequate or better for target localization. Conclusions: A lower-dose cone-beam computed tomography protocol demonstrated table shift vector magnitude that approximate clinical target volume/planning target volume expansions used in central nervous system radiotherapy. There were no significant clinical predictors of setup accuracy identified, supporting use of this lower-dose cone-beam computed tomography protocol across a diverse pediatric population with brain tumors.
KW - brain neoplasms
KW - IGRT
KW - image-guided
KW - prospective study
KW - radiotherapy
UR - http://www.scopus.com/inward/record.url?scp=85084031096&partnerID=8YFLogxK
U2 - 10.1177/1533033820920650
DO - 10.1177/1533033820920650
M3 - Journal article
C2 - 32329413
AN - SCOPUS:85084031096
SN - 1533-0346
VL - 19
JO - Technology in Cancer Research and Treatment
JF - Technology in Cancer Research and Treatment
ER -