T1 - Helium pencil beam commissioning and beam modeling
AU - Martin, Lukas
AU - Knäusl, Barbara
AU - Kuess, Peter
AU - Georg, Dietmar
AU - Palmans, Hugo
AU - Wolf, Lorenz
AU - Gambino, Nadia
AU - Farinon, Fabio
AU - Prochazka, Andrej
AU - Schafasand, Mansure
AU - Glimelius, Lars
AU - Ikegami Andersson, Walter
AU - Simon Colomar, Daniel
AU - Carlino, Antonio
AU - Stock, Markus
AU - Fuchs, Hermann
N1 - Publisher Copyright:
© 2026 The Authors. Published by Elsevier B.V. on behalf of European Society of Radiotherapy & Oncology. This is an open access article under the CC BY license. http://creativecommons.org/licenses/by/4.0/
PY - 2026/7/1
Y1 - 2026/7/1
N2 - Background and Purpose: Helium ions combine reduced lateral scattering compared to protons and a lower fragmentation tail than carbon ions, enabling sharp dose gradients and improved normal tissue sparing. This study reports the commissioning of a scanned helium pencil beam line and validation of its corresponding beam model. Materials and Methods: Synchrotron-based helium ion beams were commissioned covering energies from 54.6 to 402.8MeV/u. Depth–dose curves were measured and absolute dose calibration was performed. Beam optics (spot size, position, and intraspill stability) were evaluated for various spill lengths. A beam model was implemented in the RayStation treatment planning system (TPS) and validated through 2D absolute dose measurements in homogeneous and heterogeneous phantoms and 3D measurements of cubic spread-out Bragg peak fields. Gamma-index analysis and Monte Carlo (MC) simulations with GATE/Geant4 were performed for benchmarking. Results: Measured ranges agreed with MC simulations within ±[jls-end-space/]0.3mm. Spot sizes decreased with energy, independently of the spill length. Spot positions remained within ±[jls-end-space/]0.5mm and intraspill variations were ≤[jls-end-space/]0.2mm (position) and ≤[jls-end-space/]5.4% (size). TPS-predicted doses agreed within 0.1%. For 3D validations in homogeneous phantoms, the dose differences were generally within 2%. Median gamma pass rates exceeded 90% for 3%/1.5mm and 95% for 5%/1.5mm. For the heterogeneous phantom, differences were within -3.2%. Conclusions: Stable scanned beam delivery with helium ions was established. Validation demonstrated strong agreement between measurements, TPS calculations, and MC simulations, supporting research and future clinical application.
AB - Background and Purpose: Helium ions combine reduced lateral scattering compared to protons and a lower fragmentation tail than carbon ions, enabling sharp dose gradients and improved normal tissue sparing. This study reports the commissioning of a scanned helium pencil beam line and validation of its corresponding beam model. Materials and Methods: Synchrotron-based helium ion beams were commissioned covering energies from 54.6 to 402.8MeV/u. Depth–dose curves were measured and absolute dose calibration was performed. Beam optics (spot size, position, and intraspill stability) were evaluated for various spill lengths. A beam model was implemented in the RayStation treatment planning system (TPS) and validated through 2D absolute dose measurements in homogeneous and heterogeneous phantoms and 3D measurements of cubic spread-out Bragg peak fields. Gamma-index analysis and Monte Carlo (MC) simulations with GATE/Geant4 were performed for benchmarking. Results: Measured ranges agreed with MC simulations within ±[jls-end-space/]0.3mm. Spot sizes decreased with energy, independently of the spill length. Spot positions remained within ±[jls-end-space/]0.5mm and intraspill variations were ≤[jls-end-space/]0.2mm (position) and ≤[jls-end-space/]5.4% (size). TPS-predicted doses agreed within 0.1%. For 3D validations in homogeneous phantoms, the dose differences were generally within 2%. Median gamma pass rates exceeded 90% for 3%/1.5mm and 95% for 5%/1.5mm. For the heterogeneous phantom, differences were within -3.2%. Conclusions: Stable scanned beam delivery with helium ions was established. Validation demonstrated strong agreement between measurements, TPS calculations, and MC simulations, supporting research and future clinical application.