A Novel Echocardiographic Parameter to Confirm Low-Gradient Aortic Stenosis Severity

Sébastien Hecht, Mohamed-Salah Annabi, Viktória Stanová, Abdellaziz Dahou, Ian G Burwash, Matthias Koschutnik, Philipp E Bartko, Jutta Bergler-Klein, Julia Mascherbauer, Carolina Donà, Stefan Orwat, Helmut Baumgartner, Joao L Cavalcante, Henrique B Ribeiro, Alexis Théron, Josep Rodes-Cabau, Marie-Annick Clavel, Philippe Pibarot

Research output: Journal article (peer-reviewed)Journal article

Abstract

Background: In patients with low-gradient (LG) aortic stenosis (AS), confirming disease severity and indication of intervention often requires dobutamine stress echocardiography (DSE) or aortic valve calcium scoring by computed tomography. We hypothesized that the mean transvalvular pressure gradient to effective orifice area ratio (MG/EOA, in mm Hg/cm 2) measured during rest echocardiography identifies true-severe AS (TSAS) and is associated with clinical outcomes in patients with low-flow, LG-AS. Objectives: The purpose of this study was to evaluate the diagnostic and prognostic value of MG/EOA ratio. Methods: The diagnostic accuracy of MG/EOA ratio to identify TSAS was retrospectively assessed in: 1) an in vitro data set obtained in a circulatory model including 93 experimental conditions; and 2) an in vivo data set of 188 patients from the TOPAS (True or Pseudo-Severe Aortic Stenosis) study (NCT01835028). Receiver operating characteristic curves were used to assess the diagnostic accuracy of MG/EOA ratio for identifying TSAS, and Cox proportional hazards regression analyses were performed to assess its association with clinical outcomes. Results: The optimal cutoff of MG/EOA ratio to identify TSAS in patients with low-flow, LG-AS was ≥25 mm Hg/cm 2 (correct classification 85%), as well as in vitro (100%). During a median follow-up of 1.41 ± 0.75 years, 146 (78%) patients met the composite endpoint of aortic valve replacement or all-cause mortality. A MG/EOA ratio ≥25 mm Hg/cm 2 was independently associated with an increased risk of the composite endpoint (adjusted HR: 2.36 [95% CI: 1.63-3.42], P < 0.001). The Harell's C-index of MG/EOA was 0.68, equaling projected EOA (0.67) measured by DSE. Conclusions: MG/EOA ratio can be useful in low-flow, LG-AS to confirm AS severity and may complement DSE or aortic valve calcium scoring.

Original languageEnglish
Article number101245
Pages (from-to)101245
JournalJACC: Advances
Volume3
Issue number10
DOIs
Publication statusPublished - Oct 2024

Keywords

  • aortic stenosis
  • echocardiography
  • dobutamine stress
  • low-flow low-gradient

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Dentistry (miscellaneous)

Fingerprint

Dive into the research topics of 'A Novel Echocardiographic Parameter to Confirm Low-Gradient Aortic Stenosis Severity'. Together they form a unique fingerprint.

Cite this