TY - JOUR
T1 - Rotational stability in screw-fixed scaphoid fractures compared to plate-fixed scaphoid fractures
AU - Jurkowitsch, Josef
AU - Dall’Ara, E.
AU - Quadlbauer, S.
AU - Pezzei, Ch
AU - Jung, I.
AU - Pahr, D.
AU - Leixnering, M.
N1 - Publisher Copyright:
© 2016, Springer-Verlag Berlin Heidelberg.
PY - 2016/11/1
Y1 - 2016/11/1
N2 - Background: The literature describes the treatment of scaphoid fractures comparing the volar and dorsal approaches, the advantages and disadvantages of percutaneous screw fixation, as well as the treatment of scaphoid nonunions using different types of cancellous or corticocancellous bone grafts. Yet, to date no studies are available comparing the outcome of rotational stability in screw-fixed scaphoid fractures to angular stable systems. The purpose of this study is to provide reliable data about rotational stability in stabilised scaphoid fractures and to gain information about the rigidity and the stability of the different types of fixation. Methods: Three groups of different stabilisation methods on standardised scaphoid B2 fractures were tested for rotational stability. Stabilisation was achieved using one or two cannulated compression screws (CCS) or angular stable plating. We performed ten repetitive cycles up to 10°, 20° and 30° rotation, measuring the maximum torque and the average dissipated work at angle level. Results: Our study showed that rotational stability using a two CCS fixation is significantly (p < 0.05) higher than single CCS fixation. Using the angular stable plate system was also superior to the single CCS (p < 0.05). There was, however, no significant difference between two CCS fixation and angular stable plate fixation. Conclusion: Even though indications of using screws or plate systems might be different and plate osteosynthesis may be preferable in treatment of dislocated or comminuted fractures as well as for nonunions, our study showed a better rotational stability by choosing more than just one screw for osteosynthesis. Angular stable plating of scaphoid fractures also provides more rotational stability than single CCS fixation. The authors therefore hypothesise higher union rates in scaphoid fractures using more stable fixation systems.
AB - Background: The literature describes the treatment of scaphoid fractures comparing the volar and dorsal approaches, the advantages and disadvantages of percutaneous screw fixation, as well as the treatment of scaphoid nonunions using different types of cancellous or corticocancellous bone grafts. Yet, to date no studies are available comparing the outcome of rotational stability in screw-fixed scaphoid fractures to angular stable systems. The purpose of this study is to provide reliable data about rotational stability in stabilised scaphoid fractures and to gain information about the rigidity and the stability of the different types of fixation. Methods: Three groups of different stabilisation methods on standardised scaphoid B2 fractures were tested for rotational stability. Stabilisation was achieved using one or two cannulated compression screws (CCS) or angular stable plating. We performed ten repetitive cycles up to 10°, 20° and 30° rotation, measuring the maximum torque and the average dissipated work at angle level. Results: Our study showed that rotational stability using a two CCS fixation is significantly (p < 0.05) higher than single CCS fixation. Using the angular stable plate system was also superior to the single CCS (p < 0.05). There was, however, no significant difference between two CCS fixation and angular stable plate fixation. Conclusion: Even though indications of using screws or plate systems might be different and plate osteosynthesis may be preferable in treatment of dislocated or comminuted fractures as well as for nonunions, our study showed a better rotational stability by choosing more than just one screw for osteosynthesis. Angular stable plating of scaphoid fractures also provides more rotational stability than single CCS fixation. The authors therefore hypothesise higher union rates in scaphoid fractures using more stable fixation systems.
KW - Angular stable plate
KW - Biomechanic
KW - Fracture
KW - Headless compression screw
KW - Nonunion
KW - Rotational stability
KW - Scaphoid
UR - http://www.scopus.com/inward/record.url?scp=84983775211&partnerID=8YFLogxK
U2 - 10.1007/s00402-016-2556-z
DO - 10.1007/s00402-016-2556-z
M3 - Journal article
C2 - 27566618
AN - SCOPUS:84983775211
SN - 0936-8051
VL - 136
SP - 1623
EP - 1628
JO - Archives of Orthopaedic and Trauma Surgery
JF - Archives of Orthopaedic and Trauma Surgery
IS - 11
ER -