Abstract

This study validated two different high-resolution peripheral quantitative computer tomography (HR-pQCT)-based finite element (FE) approaches, enhanced homogenised continuum-level (hFE) and micro-finite element (μFE) models, by comparing them with compression test results of vertebral body sections. Thirty-five vertebral body sections were prepared by removing endplates and posterior elements, scanned with HR-pQCT and tested in compression up to failure. Linear hFE and μFE models were created from segmented and grey-level CT images, and apparent model stiffness values were compared with experimental stiffness as well as strength results. Experimental and numerical apparent elastic properties based on grey-level/segmented CT images (N = 35) correlated well for μFE (r 2=0.748/0.842) and hFE models (r 2=0.741/0.864). Vertebral section stiffness values from the linear μFE/hFE models estimated experimental ultimate apparent strength very well (r 2=0.920/0.927). Calibrated hFE models were able to predict quantitatively apparent stiffness with the same accuracy as μFE models. However, hFE models needed no back-calculation of a tissue modulus or any kind of fitting and were computationally much cheaper.

OriginalspracheEnglisch
Seiten (von - bis)711-720
Seitenumfang10
FachzeitschriftComputer Methods in Biomechanics and Biomedical Engineering
Jahrgang15
Ausgabenummer7
DOIs
PublikationsstatusVeröffentlicht - Juli 2012
Extern publiziertJa

ASJC Scopus Sachgebiete

  • Bioengineering
  • Biomedizintechnik
  • Human-computer interaction
  • Angewandte Informatik

Fingerprint

Untersuchen Sie die Forschungsthemen von „HR-pQCT-based homogenised finite element models provide quantitative predictions of experimental vertebral body stiffness and strength with the same accuracy as μFE models“. Zusammen bilden sie einen einzigartigen Fingerprint.

Dieses zitieren