Zur Hauptnavigation wechseln Zur Suche wechseln Zum Hauptinhalt wechseln

Comparable long-term results for porcine and pericardial prostheses after isolated aortic valve replacement

  • Martin Andreas
  • , Stephanie Wallner
  • , Kurt Ruetzler
  • , Dominik Wiedemann
  • , Marek Ehrlich
  • , Georg Heinze
  • , Thomas Binder
  • , Anton Moritz
  • , Michael J Hiesmayr
  • , Alfred Kocher
  • , Guenther Laufer

Publikation: Beitrag in Fachzeitschrift (peer-reviewed)Artikel in Fachzeitschrift

Abstract

OBJECTIVES: Outcome of aortic valve replacement may be influenced by the choice of bioprosthesis. Pericardial heart valves are described to have a favourable haemodynamic profile compared with porcine valves, although the clinical notability of this finding is still controversially debated. Herein, we compared the long-term results of two commonly implanted bioprosthesis at a single centre. METHODS: All consecutive patients undergoing isolated aortic valve replacement with either a Carpentier-Edwards Magna pericardial prosthesis or a Medtronic Mosaic porcine prosthesis between 2002 and 2008 were analysed regarding preoperative characteristics, shortand long-term survival, valve-related complications and echocardiographic findings. RESULTS: The Medtronic Mosaic was implanted in 163 patients and the Carpentier-Edwards Magna in 295 patients. The sizes of implanted valves were 22.4 ± 1.5 mm for the Mosaic and 21.8 ± 1.8 mm for the Magna (P = 0.001). The long-term survival rate was 76 and 56% after 5 and 10 years for the Medtronic Mosaic, which was comparable with the Carpentier-Edwards Magna (77 and 57%; P = 0.92). Overall longterm survival was comparable with an age- and sex-matched Austrian general population for both groups. Valve-related adverse events were similar between groups. The postoperative mean transvalvular gradient was significantly increased in the Mosaic group (24 ± 9 mmHg vs 17 ± 7 mmHg; P < 0.001). CONCLUSIONS: Both types of aortic bioprostheses offer excellent results after isolated aortic valve replacement. Despite relevant differences in gradients, long-term survival was comparable with the expected normal survival for both bioprostheses. Patients with a porcine heart valve had a higher postoperative transvalvular gradient.

OriginalspracheEnglisch
Seiten (von - bis)557-561
Seitenumfang5
FachzeitschriftEuropean Journal of Cardio-thoracic Surgery
Jahrgang48
Ausgabenummer4
DOIs
PublikationsstatusVeröffentlicht - Okt. 2015
Extern publiziertJa

Fingerprint

Untersuchen Sie die Forschungsthemen von „Comparable long-term results for porcine and pericardial prostheses after isolated aortic valve replacement“. Zusammen bilden sie einen einzigartigen Fingerprint.

Dieses zitieren